Flamco Flexcon Premium Expansion Vessel 18 Litres 0.5 Bar Red

- 18 liter inhoud
- 3/4inch aansluiting
- Voor cv-installaties
- Voor montage met standard expansievat koppelingen
- 0.5 bar voordruk
Description
This Flamco Flexcon Premium expansion vessel 18 litres red with 0.5 bar pre-charge pressure and 3/4 inch connection is suitable for sealed central heating systems, underfloor heating, pellet boilers and cooling systems. The expansion vessel absorbs pressure fluctuations and helps prevent overpressure, malfunctions and leaks within heating or cooling installations. This Flamco Flexcon Premium expansion vessel features a high-quality TPO diaphragm, nitrogen filling and a robust steel housing for stable operation and a long service life. Thanks to its maximum working pressure of 3 bar, the vessel is suitable for many common heating systems in residential properties and smaller commercial buildings.
An expansion vessel prevents the pressure in your heating system from becoming too high when the system water expands. The diaphragm separates water and gas, allowing pressure fluctuations to be absorbed and ensuring safe and stable operation.
- Yes → if you have a sealed central heating system
- Yes → if you need an 18 litre expansion vessel
- Yes → if your installation is suitable for 0.5 bar pre-charge pressure
- Yes → if you need an expansion vessel with a maximum working pressure of 3 bar
- Yes → for many boilers, radiators, underfloor heating systems, cooling systems and pellet boiler installations
- No → if you need an expansion vessel for potable water, domestic hot water or solar thermal systems
What does a Flamco Flexcon Premium 18 litre expansion vessel do?
An expansion vessel absorbs the increase in water volume when heating water expands. As water heats up inside a central heating system, it expands. Without an expansion vessel, pressure inside the system could rise excessively, causing the safety relief valve to open or placing unnecessary stress on system components.
The Flamco Flexcon Premium expansion vessel contains a high-quality TPO diaphragm that separates the system water from a gas chamber. As system pressure increases, the diaphragm moves and absorbs the additional volume. When the water cools, the diaphragm returns to its original position, helping maintain a stable system pressure.
An expansion vessel must match the volume, installation height and pressure requirements of the system. Always verify that 18 litres, 0.5 bar pre-charge pressure and a maximum working pressure of 3 bar are suitable for your installation.
Want more information about installation or replacement? Visit our dutch knowledge base: Installing and connecting an expansion vessel .
When do you choose a Flamco Flexcon Premium 18 litre expansion vessel?
A Flamco Flexcon Premium 18 litre expansion vessel is a suitable choice when your heating or cooling installation requires a medium-sized expansion volume. This capacity is commonly used in residential heating systems and smaller commercial installations with radiators, underfloor heating or a combination of both.
- Suitable for many standard residential heating systems
- Popular choice for boiler and radiator installations
- Suitable for underfloor heating systems
- Suitable for sealed heating and cooling systems
- Suitable for pellet boiler installations
- Ideal for replacing an existing 18 litre expansion vessel
Replacing an existing expansion vessel? Always check the vessel capacity, pre-charge pressure, connection size and maximum working pressure. If these specifications match 18 litres, 0.5 bar, a 3/4 inch connection and a maximum working pressure of 3 bar, this Flamco Flexcon Premium expansion vessel is often a suitable replacement.
What does a 0.5 bar pre-charge pressure mean?
The 0.5 bar pre-charge pressure is the factory-set pressure inside the expansion vessel. This pressure helps maintain the correct balance within the heating or cooling system and should match the installation height and operating pressure of the system.
The correct pre-charge pressure prevents excessive pressure fluctuations. This improves expansion vessel performance, helps maintain system stability and reduces unnecessary stress on components such as the pressure relief valve.
The required pre-charge pressure depends on installation height and system pressure. If in doubt, consult a qualified installer.
Suitable for which applications?
This Flamco Flexcon Premium expansion vessel 18 litres – 0.5 bar is designed for sealed heating and cooling systems where stable pressure regulation is essential. It is widely used in residential and light commercial installations.
- Central heating boilers with radiators
- Underfloor heating systems
- Pellet boilers and biomass boilers
- Sealed heating systems
- Sealed cooling systems
- Small commercial buildings
- Pellet stoves with central heating connection
Looking for installation accessories or replacement parts? Also view our expansion vessel accessories, pipes and tubing and complete expansion vessel range.
This expansion vessel is often used as a replacement for an existing 18 litre expansion vessel in homes with central heating systems, underfloor heating, cooling systems or pellet boiler installations.
Installation and connection
The Flamco Flexcon Premium expansion vessel is equipped with a 3/4 inch connection and can easily be connected to standard heating pipework. The standard connection makes it compatible with commonly used accessories such as expansion vessel couplings, wall brackets, mounting consoles and combined mounting sets.
For proper operation, the expansion vessel must be installed correctly and matched to the system pressure requirements. Always verify the pre-charge pressure, installation height, maximum working pressure and condition of existing components.
Before installation, always check the system pressure, pre-charge pressure, connection size and vessel capacity. Professional installation is recommended if you are unsure.
Want to learn more about installation or replacement? Go to our download section.
When should you replace a Flamco Flexcon Premium expansion vessel?
Expansion vessels wear over time. In particular, the diaphragm inside the vessel may eventually fail, preventing the vessel from effectively absorbing pressure fluctuations.
- Central heating pressure fluctuates frequently
- The pressure relief valve regularly discharges water
- You need to refill the system often
- The expansion vessel no longer provides counter pressure
- You hear knocking or flow noises in the installation
If you are replacing an existing expansion vessel, always verify that the capacity, pre-charge pressure, connection size and maximum working pressure match the original vessel or the requirements of your installation.
Is this Flamco Flexcon Premium 18 litre expansion vessel suitable for your installation?
This expansion vessel is suitable if:
- you have a sealed heating system
- you have a sealed cooling system
- you require an 18 litre vessel
- your installation requires 0.5 bar pre-charge pressure
- you need a maximum working pressure of 3 bar
- you use radiators, underfloor heating or a pellet boiler
- you are replacing an existing 18 litre expansion vessel
Choose a different vessel if:
- your system requires a different pre-charge pressure
- you need a larger or smaller expansion volume
- you need an expansion vessel for potable water
- you have a solar thermal installation
- you are unsure about system volume or pressure requirements
Why choose a Flamco Flexcon Premium 18 litre expansion vessel?
Flamco is recognised worldwide for high-quality expansion vessels used in heating and cooling systems. The Flexcon Premium range is designed to deliver reliable pressure control, long service life and dependable performance.
The combination of a premium TPO diaphragm, nitrogen filling, robust steel housing, 0.5 bar pre-charge pressure, 3 bar maximum working pressure and standard 3/4 inch connection makes this vessel suitable for a wide range of residential and commercial applications.
If you are looking for a reliable Flamco Flexcon Premium 18 litre expansion vessel for radiators, underfloor heating, cooling systems or pellet boiler installations, this model is a durable and practical choice.
The Flamco Flexcon Premium range has been developed for reliable pressure regulation in sealed heating and cooling systems. The advanced TPO diaphragm offers extremely low gas permeability, helping maintain the vessel's pre-charge pressure for longer. Combined with nitrogen filling and durable construction, this results in outstanding long-term performance.
This Flamco expansion vessel is ideal for sealed heating and cooling systems where reliable pressure control is essential. Combine it with suitable mounting accessories and expansion vessel fittings for a complete and professional installation.
Technische specificaties
| Article number | 16916 |
| EAN nummer | 8712874169166 |
| Brand | Flamco |
| Model | expansion vessel |
| Diameter | 256 mm |
| Thread type | BSP (G-thread) |
| Thread size | 3/4 inch |
| Max operating temperature | 0°C to 70°C |
| Peak temperature | 70 °C |
| Max operating pressure | 3 bar |
| Certification | ce |
| Application | Heating |
| Collecties 2 | Central heating expansion vessels |
| Height | 405 mm |
| Pre charge pressure | 0.5 bar |
| Volume | 18 liter |
| Material | Steel TPO |
| Nominal diameter | DN20 |
| Color | Red |
| Finish | Epoxy-coated steel |
| Thread connection | External thread |
Documenten en/of handleidingen